Ionostim PROFESSIONAL ELECTROTHERAPY


Ionostim produces therapeutic diadinamic current for painful muscular inflammations, joints, periphery nerves and in sport medicine, for fast solution of traumas and hematomas. Faradic currents for muscle stimulation. Continuous current (galvanic) that can be generated singularly or mixed with diadinamic and faradic current. T.E.N.S. current for analgesic treatments. The device is completely controlled by a microprocessor and it presents 2 output conduits. The device operates on the base of selected parameters or memorized programs.

ITALIAN, ENGLISH AND FRENCH INCORPORATED SOFTWARE
40 PRE-SET PROGRAMMES

ACCESSORIES INCLUDED
– 1 feeding cable 2m
– 2 small red cables with 4mm connectors
– 2 small black cables with 4mm connectors
– 4 80x120mm conductive silicone electrodes with 4mm holes
– 4 sponge casings for 80x120mm electrodes
– 4 50x50mm conductive silicone electrodes
– 4 sponge casings for 50x50mm electrodes
– 2 8x100cm elastic bands with Velcro fasteners to stop the electrodes
– 2 8x60cm elastic bands with Velcro fasteners to stop the electrodes

PRODUCT CODE: LTE320 Category ,

Technical features

Reference Standards and Directives
Directive 93/42/EEC
Quality Ass. standard EN ISO 9001 (2000), UNI EN 13485 (2002)
Safety standards:EN60601-1, EN60601-2-10, EN60601-1-2

Feeding: 230V ~ / 50 Hz
Power consumption: 22VA
Internal fuse: T 500mA
Impulsive current max: 60mA
Continuous current max: 20mA
Output voltage: 100 Vdc
Number of conduits: 2
Treatment time: from 1 to 60 min
Output param. indicator: Alphanumeric Display
Output indicator: Visual
Electric safety class: II BF
Protection level: IP20

Function

– Current Faradic
(Rectangular, Triangular, Exponential)
Galvanic association: Yes
Polarity: Positive / Negative
Impulse duration: 1 μ sec
Frequency: 1, 2, 5, 10, 20, 50, 100, 200, 500Hz
Action time: from 3 to 60 sec
Break time: from 0 to 60 sec

– Current impulsive
(Rectangular, Triangular, Exponential)
Galvanic association: No
Polarity: Positive / Negative
Impulse duration: 1, 2, 5, 10, 20, 50, 100, 200 μsec
Break time: from 1 to 10 sec

– Current diadinamic
Galvanic association: Yes
Polarity: Positive / Negative
MF Frequency: 50Hz
MFS Frequency: 50Hz
Action time: 1 sec
Break time: 1 sec
DF Frequency: 100Hz
DFS Frequency: 100Hz
Action time: 1 sec
Break time: 1 sec
CP: Frequency 50Hz for 1 sec
100Hz for 1 sec

LP: Frequency 50Hz for 5 sec
100Hz for 7 sec

– Current T.E.N.S
Galvanic association: No
Polarity: Positive / Negative
Impulse duration: 100, 150, 200, 250, 300 μsec
Frequency: 1, 2, 5, 10, 20, 50, 100, 200, 500Hz