A-PAP AUTOMATIC POSITIVE AIRWAY PRESSURE DEVICE


Obstructive Sleep Apnea (OSA) is an intermitted and repetitive obstruction of the upper respiratory tract that completly (apnea) or partially (hypopnea) blocks the breathing airflow during sleep. The syndrome varies according to the degree of relaxation of the tongue and soft palate muscle. The most common treatment for OSA is Continuous Positive Airway Pressure (CPAP).


 


CPAP devices can give a constant air pressure to your upper respiratory tract through a nasal mask. This constant air pressure can keep your airway open during sleep and prevent the OSA. This device permits to regulate the ramp time. This allows the patient to fall asleep comfortably while the air pressure reaches slowly the right level for the treatment. The user compliance meter records the total system’s operating time for physician’s reference.

WARNING! Some functioning parameters are preset according to common therapeutic requirements. We recommend to let your doctor or qualified personnel check any variation.

PRODUCT CODE: LTK310 Category →

Technical features


– Compact, lightweight, portable

– LCD display with backlight and easy to use interface

– The APAP adjusts automatically the airflow pressure, according to the patient’s 

   needs throughout the night

– Data recording on Mini SD memory card

– Enhanced pressure sensor for better pressure accuracy

– The automatic variation of loss and altitude adjustment guarantee a careful 


   pressure release and an optimal treatment

– Noiseless

– USB cable




– CD data management software

– Power supply: AC100-240V, 50/60 Hz, 0,5-0,3A

– Pressure range: 4-20 cm H2O (0,5 cm H2O increment)

– Initial Pressure: 3-19 cmH2O (adjustable in 0.5 cmH2O increment)

– Maximum Pressure: 5-20 cmH2O (adjustable in 0.5 cmH2O increment)

– Minimum Pressure: 4-19 cmH2O (adjustable in 0.5 cmH2O increment)

– Ramp time: 0-45 minutes (5 minutes increment)

– Ramp starting: pressure 3-19 cm H2O (0,5 cm H2O increment)

– Altitude Compensation (Manual setting)*: Level 1~8 for 0 ~8000ft / 2438m when the pressure set at 4-18 cmH2O, Level 1~5 for 0~5000ft / 1524m when the pressure set at 18.5-20 cmH2O

– Noise level: From 30 dBA to 10 cm H2O, 1 m distance

*LTK310 A-PAP can also be used in C-PAP mode, the above parameters can be changed from qualified medical staff only


Dimensions: L:14,8 x W:12,8 x H:10 cm


Weight: 800g


 


 















Models

LTK300

LTK305

LTK310

Auto adjustable pressure

 

 

•

Limiting function of the PVA pressure

 

 

•

Losses compensation

•

•

•

Low pressure alarm

 

•

•

Data collection from SD card

 

•

•

Efficacy signal

 

 

•

Conformity record

•

•

•

Remote updating about pressure adjustment

 

 

•

Function watch/alarm clock

 

 

•

Heated humidifier

•

•

•


 


 


Accessories needed for C-PAP operation (NOT INCLUDED):

LTK340 (Small) – LTK341 (Medium) – LTK342 (Large) Nasal Mask

LTK335 (Small) – LTK336 (Medium) – LTK337 (Large) The facial mask is suitable for people with nasal respiration problems

LTK345​ Flexible tube

Download

Close
Close