PATIENT MONITOR MULTIPARAMETER – DISPLAY 12,1″

High resolution colour TFT-LCD display. Visualization of ECG, RESP, SpO2, NIBP, PR, 2-TEMP. Suitable for adult, pediatric and neonatal patients. Arrhythmia analysis. Pacemaker detection, defibrillation and electrosurgical interference protection. 96 hours trend review, 500 NIBP measurements and 60 alarm memory. USB port. With handle for transport. Optional built-in printer.

Codes
LTD345
LTD347 – CO2 RESPIRONICS
LTD348 – CORESPIRONICS + IBP
LTD357 – CO2
LTD358 – CO2 + IBP

Accessori INCLUDED
– 1 Five lead ECG Cable, snap, Defib, IEC, 3.5m, reusable
– 30 ECG Electrodes, adult, disposable
– 1 SPO2 Finger Sensor, adult, 2.5m, reusable
– 1 NIBP Cuff, Adult, 25cm-35cm, reusable
– 1 NIBP Tube, 3m
– 1 Temperature Probe Skin, adult, 3m, reusable
– 1 Power Cord (EUR standard)
– 1 Rechargeable Lithium-Ion Battery (14.8V, 2100mAh)
– 1 Ground Cable

Languages available on request 
 Italian
 English
 Spanish
 French
 Portuguese
 German
 Polish
 Chinese
 Turkish

PRODUCT CODE: LTD3xx, LTD345, LTD347, LTD348, LTD357, LTD358 Category

Technical features

Display
Colour TFT LCD: 12,1”
Resolution: 800×600
Traces displayed: Up to 8
Waveforms displayed: Up to 11
Sweep Speed: 6.25, 12.5, 25, 50 mm/s 

ECG
Lead Type: 5-lead and 3-lead selectable
Gain: Auto, x 0.125, x 0.25, x 0.5, x 1, x 2, x 4
Sweep Speed: 6.25, 12.5, 25, 50 mm/s
ECG HR Range:
Adult: 15~300bpm
Pediatric/Neonate: 15~350bpm
Resolution: 1 bpm
Accuracy: ±1 bpm or ±1% (whichever is greater)
Filter: Diagnostic mode 0.05 – 150 Hz / Monitoring mode 0.5 –  40 Hz / Surgical mode 1 – 20 Hz
Diagnostic Mode: 0.05~150 Hz
Monitoring Mode: 0.5~40 Hz
Surgical Mode: 1~20 Hz
ST-Segment Detection
Measurement Range: -2.0 mV~2.0 mV
Alarm Range: -2.0 mV~2.0 mV 

RESP
Method: Trans-thoracic impedance
Operation Mode: Auto/Manual
– RR Measurement Range:
Adult:0~120 rpm
Neonate/Pediatric: 0~150 rpm
Resolution: 1 rpm
Apnea Alarm Thresold: 10,15,20,25,30,35,40 s
Band Width: 0.2-2.5 Hz (-3 dB)
Sweep Speed: 6.25, 12.5, 25, 50 mm/s 

SpO2
Measurement & Alarm Range: 0~100% (EDAN SpO2)
Resolution: 1%
Accuracy:
±2% (70~100% Adult/Pediatric)
±3% (70~100% Neonate)
PR Measurement: 25~300 bpm
Resolution: 1bpm
Refresh Rate: 1 second 

NIBP
Method: Automatic Oscillometric
Operation Modes: Manual/Automatic/Continuous
Auto Measurement Time Interval:
1,2,3,4,5,10,15,30,60,90,120,240,480 minutes
Measurement Unit: mmHg/kPa
Measurement Types: Systolic, Diastolic, Mean
Pressure Range:
Adults:
Systolic: 40~270 mmHg
Diastolic: 10~215 mmHg
Mean: 20~235 mmHg
Pediatrics:
Systolic: 40~200 mmHg
Diastolic: 10~150 mmHg
Mean: 20~165 mmHg
Neonates:
Systolic: 40~135 mmHg
Diastolic: 10~100 mmHg
Mean: 20~110 mmHg
Resolution: 1 mmHg
Accuracy:
Max Mean error: ±5 mmHg
Max Standard Deviation: 8 mmHg
PR from NIBP Measurement Range: 40~240 bpm
Resolution: 1bpm
Accuracy: 3 bpm or 3.5% (whichever is greater)
SP10: 2002 

LTD346 & LTD348 ONLY IBP (2 Channels)
Measurement Pressure: ART, PA, CVP, RAP, LAP,ICP, P1,P2
Measurement Range: -50~300 mmHg
Resolution: 1 mmHg
Accuracy: ±2% or ±1 mmHg (whichever is greater, without probe)
Sensitivity: 5 μV/V/mmHg
Impedance Range: 300~3000Ω 

LTD347 & LTD348 ONLY CO2
Type: Sidestream/Mainstream
Range: 0~150 mmHg
Accuracy:
±2 % – 0~40 mmHg
±5% – 41~70 mmHg
±8% – 71~100 mmHg
±10% – 101~150 mmHg
AwRR Accuracy: ±1 rpm 

Temperature (2 Channels, 1 probe by default)
Measurement/Alarm Range: 0~50C° (32-122 F°)
Resolution: 0.1 C°
Accuracy: ±0.1 C° (without probe)
Channel: Dual-Channel- Provide T1; T2; ΔT 

Power Supply
AC Power: 100~240 V AC, 50/60 Hz
Battery: 14.8 V Rechargeable Li-ion Battery
Dimensions  L:32 x W:15 x H:26,5 cm
Weight 5 kg